Call The Experts

ARMATHERM GF

<< back to Products

Introduction

Armatherm™ GF Grade Thermal Break Pads deliver deliver high performance thermal insulation between interior and exterior steelwork and / or concrete to prevent thermal bridging. Cutting out thermal bridging stops conduction heat loss and prevents surface condensation from forming inside the building that can be due to cold transfer meeting warm air

Specifications of Armatherm

Maximum Loading Pressure N/mm2103
Strain at Maximum Pressure10%
Compressive Modulus N/mm2600
Shear Strength N/mm275
Standard Thickness 13mm, 19mm, 25mm, & 50mm
Density Kg/M31300
Thermal Conductivity W/m°K0.196
Minimum Operating Temp °C-30
Maximum Operating Temp °C82

For comparison, the thermal conductivity of Mild Steel is 56 W/m°K

Washer and Bushing

With a bolt through insulation pad there is the possibility of a slight thermal transfer along the connecting bolt

For the majority of installations this can be ignored, however this effect can be reduced with the addition of Insulation washers and bushing

In extreme applications (e.g. Swimming Pools), to prevent condensation on the bolt head, a polyurethane nut cap can be supplied to effectively screen this cold surface from the internal environment

BUSHING DETAIL

Bolt Size Hole in Pad Bushing ID Bushing OD Hole in Structure Bushing Length
M12 14 14 20 20 10
1/2" 0.55" 0.55" 0.78" 0.78" 0.375
M16 18 18 24 24 13
5/8" 0.70" 0.70" 1.0" 1.0" 0.50"
M20 22 22 28 28 13
3/4" 0.86" 0.86" 1.10" 1.10" 0.50"
M24 26 26 32 32 17
1" 1.05" 1.05" 1.25" 1.25" 0.625"

Armatherm

Optional Extra

Armatherm

Bolt Size Washer ID Washer OD Thickness
M12 14 30 6
1/2" 0.55" 1.18" 0.25"
M16 18 40 6
5/8" 0.7" 1.57" 0.25"
M20 22 47 6
3/4" 0.86" 1.85" 0.25"
M24 26 50 6
1" 1" 2.00" 0.25"